APO  Pyro Fuse

Series

APO Pyro fuse for active safety in high-voltage systems

Pyro Fuse

New_Logo

Description

  • Safety device to be triggered by ECU/BMS
  • To break down the main circuit via trigger device actively
  • To disconnect the battery circuit in abnormal conditions such as short circuits or collisions

Unique Selling Proposition

  • High safety and reliability
  • Mechanical vibration and shock resistance

Applications

  • Electric Vehicles (EVs)
  • Conventional Vehicle Electrical Systems
  • Charging Infrastructure
  • Photovoltaic (PV) & Energy Storage Systems (ESS)
  • Household Energy
  • Storage Electric Vessels
  • Fuel Cell Technologies
  • Aerospace (including eVTOL)

Rated Voltage

1000 VDC

Rated current

400 A

Breaking Capacity

1000 VDC/16 kA/20 µH 

Internal Resistance (@20 °C)

≤50 µΩ (before breaking) 

≥10 MΩ (after disconnection) 

Ignition resistance

≥1.7 Ω, ≤2.5 Ω 

Trigger Current

≥1.75 A /0.5 ms or ≥1.2 A/2 ms 

No Trigger Current

≤0.4 A /≤ 10 s or ≤5 A /≤0.5 µs 

Monitoring Current

< 100 mA 

Mounting

Bolt-on A

Admissible Ambient Temp.

-40 °C to 105 °C

Material: Housing

PA6

Material: Terminals

Copper alloy, tin-plated

Unit Weight

< 300 g

Storage Conditions

-40 °C to 65 °C

max. 70% r.h. @ 40 °C 

max. 80% r.h. @ 30 °C 

max. 90% r.h. @ 20 °C 

Product Marking

Schurter, Type Description, Type, Rated current, Rated Voltage

Resistance to Vibration

AK-LV 124

Current Carrying Capacity

400 A Continuous current @ 85 °C (Busbar size ≥120 mm²)

Action Time

<2 ms 

Mechanical Shock

AK-LV 124

Temperature Cycling

AK-LV 124 

Chemical resistance

AK-LV 124 

Installation

M8 screw (Copper busbar)
ISO 19072 AKII (trigger) 

Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: APO

Approval Logo Certificates Certification Body Description


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

Dimension [mm]


Electric separation time

Time summand Typical Maximum
Ignition delay 0.3 ms @1.75 A 0.5 ms @1.75 A
Mechanical separation time 0.2 ms 0.5 ms
Breaking time 0.5 ms 1.0 ms
Total switching time 1.0 ms 2.0 ms

Breaking Behavior


Short Table of Variants APO Open complete table APO

Rated current Rated Voltage Breaking Capacity Order Number
Symbols, Footprints, 3D-Models Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
[A]   [VDC]              
 
400 1000 1000 VDC/16 kA/20 µH 3-158-119 - ...

Packaging Unit Bulk 445 x 370 x 268 mm (18 pcs.)

Hazardous Materials – Safety Instructions


Short-Circuit Ring

The connector has a shorting clip. If not fully inserted, it shorts the two pins to prevent accidental activation during transport, installation, or use.


Ground Isolation

The low-voltage trigger signal must be isolated from the high-voltage system ground. A common ground or connection is prohibited.


Breaking Capacity

Do not use the fuse if the fault current exceeds its rated breaking capacity. Contact Schurter for applications with higher currents.


Dropped Units

Do not use a product that has been dropped. It must be inspected before any further use.


Physical Damage

Do not use a unit with any damage to the body or components.


Triggering Power Source

Only use designated triggering equipment. Do not use lead-acid or dry-cell batteries.


RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

-         The product's side panels can become hot during operation. Allow the unit to cool completely before touching.

-         Follow the mounting instructions carefully, ensuring all fastenings are tightened to the specified torque values.

-         Do not allow liquids or foreign objects to enter the product.

Not following these instructions can cause serious injury or damage to equipment.


HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

-         Disconnect all power before installing or working with this equipment

-        Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or severe injury.


Transportation Hazard Classification: UN2648, Class 9