DRM-A  Surface Mount Fuse, 3 x 10.1 mm, Quick-Acting F, 250 VAC, 125 VDC

Series: DRM-A

Surface Mount Fuse, 3 x 10.1 mm, Quick-Acting F, 250 VAC, 125 VDC

New_Logo Free Sample Request

24 Variants


Description

  • Designed for use with fuseholder FRM-A
  • Directly solderable on printed circuit boards
  • Impermeable to potting compound used to achieve hermetic seal for use in intrinsically safe applications according to ATEx and IECEx requirements.

Unique Selling Proposition

  • Defined interruption at 1.7 x rated current
  • Low melting I²t-values
  • Verified High Altitude Capability
  • Qualified for high altitude operation

Applications

  • Avionics
  • Ground Equipment

Rated Voltage

250 VAC, 125 VDC

Rated current

0.5 - 8 A

Breaking Capacity

100 A - 200 A

Characteristic

Quick-Acting F

Mounting

PCB,SMT

Admissible Ambient Temp.

-55 °C to 125 °C

Climatic Category

55/125/21 acc. to IEC 60068-1

Material: Housing

Ceramics

Material: Terminals

Copper alloy, gold-plated nickel

Unit Weight

0.3 g

Storage Conditions

0 °C to 40 °C, max. 70% r.h.

Product Marking

Schurter_Prüfzeichen, DRM-A, Rated current, Characteristic, Rated Voltage

Soldering Methods

Reflow, Wave
Soldering Profile

Solderability

JESD22-B102E, Method 1 

Resistance to Soldering Heat

JEDEC J-STD-020 

Solderability

245 °C / 3 sec acc. to IEC 60068-2-58, Test Td

Resistance to Soldering Heat

260 °C / 10 sec acc. to IEC 60068-2-58, Test Td

Moisture Sensitivity Level

MSL 1, J-STD-020 

Damp heat, steady state

IEC 60068-2-78

Moisture Sensitivity Level

MIL-STD-202, Method 106
(acc. to EIA/IS-722, Test 4.4.3)

Operational Life

MIL-STD-202, Method 108 Condition F
2000h @ 0.60 x In @ 125°C

Vibration, High Frequency

IEC 60068-2-6

Mechanical Shock

IEC 60068-2-27

High Temperature Exposure

IEC 60068-2-14

Resistance to Solvents

MIL-STD-202, Method 215

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: DRM-A

Approval Logo Certificates Certification Body Description
Approval marks cURus UL UR File Number: E41599


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks UL Designed according to UL 248-14 Low voltage fuses - Part 14: Supplemental fuses


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC_Certification_Body Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_50_non_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety Halogenfree SCHURTER AG SCHURTER strives to offer our customers halogen free products.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

010010230000000357
LOADING...

Dimension [mm]

Soldering pads

Derating Curves

Percentage of Rating [%]
Ambient Temperature [°C]

Pre-Arcing Time

Rated Current In 1.0 x In min. 1.1 x In min. 1.7 x In min. 1.7 x In max. 3.0 x In min. 3.0 x In max. 10.0 x In min. 10.0 x In max.
0.5 A - 8 A 4 h 60 min 300 ms 60 min 35 ms 300 ms 1 ms 10 ms

Time-Current-Curves

Time in Seconds
Current in Amperes


Short Table of Variants DRM-A Open complete table DRM-A

Rated Current [A] Rated Voltage [VAC] Rated Voltage [VDC] Order Number
Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
 
             
0.5 250 125 3-133-762 ...
0.5 250 125 3-133-763 ...
0.63 250 125 3-133-757 ...
0.63 250 125 3-133-758 ...
0.75 250 125 3-133-755 ...
0.75 250 125 3-133-756 ...
1 250 125 3-133-753 ...
1 250 125 3-133-754 ...
1.5 250 125 3-133-751 ...
1.5 250 125 3-133-752 ...
2 250 125 3-133-749 ...
2 250 125 3-133-750 ...
2.5 250 125 3-133-747 ...
2.5 250 125 3-133-748 ...
3 250 125 3-133-745 ...
3 250 125 3-133-746 ...
4 250 125 3-133-743 ...
4 250 125 3-133-744 ...
5 250 125 3-133-731 ...
5 250 125 3-133-742 ...
6.3 250 125 3-133-729 ...
6.3 250 125 3-133-730 ...
8 250 125 3-133-472 ...
8 250 125 3-133-471 ...

1) UL: 100 A @ 250 VAC, cos φ >= 0.99; 100 A @ 125 VDC, tau < 0.5 ms

1) Internal tests at 65'000 ft: 200 A @ 125 VAC, cos φ >= 0.99; 200 A @ 125 VDC, tau < 0.5 ms

2) UL: 100 A @ 250 VAC, cos φ >= 0.99; 100 A @ 125 VDC, tau < 0.5 ms

2) Internal tests at 65'000 ft: 100 A @ 125 VAC, cos φ >= 0.99; 100 A @ 125 VDC, tau < 0.5 m

Packaging Unit
acc. IEC 60286-3 Type 2a
100 pcs in ESD-plastic bag
2000 pcs. in tape [W: 24mm and P1: 8mm] on reel [A: 33cm]

010010230000000357