TM12-111  Circuit Breaker for Equipment thermal-magnetic, Flange type, Reset type, Quick connect terminals

Series: TM12-111

Circuit Breaker for Equipment thermal-magnetic, Flange type, Reset type, Quick connect terminals

Free Sample Request

2 Variants


Description

  • Flange type:
  • TMF12-211 - Thermal-magnetic circuit breaker
  • 1 pole
  • Reset type
  • Insensitive to shock or vibration
  • Quick connect terminals 6.3 x 0.8 mm

Unique Selling Proposition

  • Tripping characteristic Fast or Slow
  • Positively trip-free release
  • Available with cover
  • Different mounting possibilities

Applications

  • Power supplies
  • Uninterruptible power supply
  • Power tools
  • Household appliances

Rated Voltage AC

AC 240 VAC

Rated Voltage DC

28 VDC

Rated current range AC

0.05 - 15 A , see approbations

Conditional short circuit capacity Inc

IEC 60934: PC1, AC 240 V: 1 kA 

Short circuit capacity Icn

IEC 60934: AC 240 V : 200 A 

AC/DC 28 V : 400 A 

Degree of Protection

front side IP40 acc. to IEC 60529

Dielectric Strength

50 Hz: > 1.5 kV
Impulse 1.2/50 μs: > 2.5 kV

Insulation Resistance

500 VDC > 100 MΩ

Endurance typical

2 x Ir: 5000 switching cycles

Endurance minimum

Reset type 
 AC : 2 x Ir , cos φ 0.6 : 
 DC : 2 x Ir , L/R = 2 - 3 ms : 
 50 switching cycles

Overload

IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6

UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75

Allowable Operation Temp.

-5 °C to 60 °C

Vibration Resistance

± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc

Shock Resistance

100 G / 6 ms
acc. to IEC 60068-2-27, test Ea

Tripping Type

Thermal-Magnetic 

Actuation Type

Reset type 

Weight

ca. 10 g

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: TM12

Approval Logo Certificates Certification Body Description
Approval marks VDE VDE VDE Certificate Number: 99673
Approval marks cURus UL UR File Number: E71572
Approval marks CSA CSA CSA Certification Record: LR 37712
Approval marks ccc CCC CCC Certificate Number: 2020970307003504


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC_Certification_Body Designed according to IEC 60934 Circuit-breakers for equipment (CBE)
Approval marks UL Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment
Approval marks ccc Designed according to GB 17701 Circuit-breaker for equipment


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC_Certification_Body Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_50_non_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

040170200000008090
LOADING...

Dimension [mm]

TMx12-111

TMx12-111SN

Installation from rear
Installation from front

Diagrams

TM12-...

TM12-...N

TM12-...S

TM12-...SN


Approval Main circuit Auxiliary circuit
  Rated current Rated Voltage AC Rated Voltage DC Rated current Rated Voltage AC Rated Voltage DC
    CSA C22.2 No. 235 0.05...15 A 240 V 28 V 2 A 3 A 120 V - - 28 V
  CSA C22.2 No. 235 0.05...16 A 240 V 28 V 1 A 240 V -
  EN 60934 0.05...16 A 240 V 28 V 1 A 240 V 28 V
  GB 17701 0.05...16 A 240 V 28 V 1 A 240 V 28 V

Typical internal resistance TMF12

Rated Current [A] Internal Resistance [Ω]
0.05 335.00
0.50 4.37
1.00 1.23
2.00 0.369
3.00 0.181
4.00 0.097
5.00 0.055
6.00 0.044
7.00 0.0231
8.00 0.0227
9.00 0.0142
10.00 0.0123
11.00 0.012
12.00 0.012
13.00 0.0108
14.00 0.0091
15.00 0.0089
16.00 0.0071

Typical internal resistance TMT12

Rated Current [A] Internal Resistance [Ω]
0.05 260.00
0.50 4.03
1.00 1.006
2.00 0.323
3.00 0.161
4.00 0.086
5.00 0.0494
6.00 0.0396
7.00 0.0257
8.00 0.0249
9.00 0.0129
10.00 0.0112
11.00 0.0111
12.00 0.0111
13.00 0.0109
14.00 0.0092
15.00 0.0090
16.00 0.0075

Effect of ambient temperature

Ambient Temperature [°C] Correction factor
-5 0.87
0 0.90
10 0.95
23 1.00
30 1.05
40 1.12
50 1.20
60 1.30

Time-Current-Curves

Time in Seconds
Multiple of Rated Current In


Ambient temperature +23°


TM F 12 - 1 2 3 A B C - 1.23
The characters are placeholders for the correspondingly keys of selections from the key tables.

TM F 12 - 1 2 3 A B C - 1.23 = Magnetic release range
Magnetic release range Configuration key
Slow T
Fast F


TM F 12 - 1 2 3 A B C - 1.23 = Mounting
Mounting Configuration key
Screwflange mounting 1


TM F 12 - 1 2 3 A B C - 1.23 = Actuation Type
Actuation Type Configuration key
Reset type 1


TM F 12 - 1 2 3 A B C - 1.23 = Terminal
Terminal Configuration key
Quick connect terminal 6.3x0.8mm 1


TM F 12 - 1 2 3 A B C - 1.23 = Auxiliary contact
Auxiliary contact Configuration key
Auxiliary contact S


TM F 12 - 1 2 3 A B C - 1.23 = Shunt terminal
Shunt terminal Configuration key
Shunt terminal N


TM F 12 - 1 2 3 A B C - 1.23 = Setting indication
Setting indication Configuration key
Setting indication R


TM F 12 - 1 2 3 A B C - 1.23 = Rated current
Rated current Configuration key
0.05 A 0.05
0.1 A 0.1
0.15 A 0.15
0.2 A 0.2
0.3 A 0.3
0.4 A 0.4
0.5 A 0.5
0.6 A 0.6
0.7 A 0.7
0.8 A 0.8
0.9 A 0.9
1.0 1
1.1 A 1.1
1.2 A 1.2
1.3 A 1.3
1.4 A 1.4
1.5 A 1.5
1.6 A 1.6
1.7 A 1.7
1.8 A 1.8
1.9 A 1.9
2.0 A 2
2.1 A 2.1
2.3 A 2.3
2.5 A 2.5
2.8 A 2.8
3.0 A 3
3.3 A 3.3
3.5 A 3.5
4.0 A 4
4.5 A 4.5
5.0 A 5
5.5 A 5.5
6.0 6
6.5 A 6.5
7.0 A 7
7.5 A 7.5
8.0 A 8
8.5 A 8.5
9.0 A 9
9.5 A 9.5
10.0 A 10
11.0 A 11
12.0 A 12
13.0 A 13
14.0 A 14
15.0 A 15
16.0 A 16
Other rated currents on request


Short Table of Variants TM12-111 Open complete table TM12-111

Rated Current [A] Construction variants Order Number Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
             
  Auxiliary contact   Shunt terminal   Setting indication          
3 4410.0228 ...
6 4410.0519 ...

Packaging Unit 20 Pcs 

040170200000008090
LOADING...

01.10.2024
   
it prod Cambiando la versione del catalogo (Desktop <> Mobile), il sistema resetta i filtri scelti